Blue-White - Chemical metering and fluid measurement solutions; chemical metering pumps, peristaltic pumps, diaphragm pumps, multi-diaphragm pumps, flow meters, flowmeters, variable area flow meters, paddlewheel flow meters, ultrasonic flow meters, engineered skid systems, single skid system, duplex skid system, triplex skid system, water analyzers...

Help Center

The Help Center is a self-service resource to view support articles, training videos, help topics, and best practices on our products. It also features our exclusive AI assistant, Oswald AI™, to assist you with any questions.

Oswald

Industrial

FLEXFLO® A-100NVP

Troubleshooting

Common Issues

Air is entering the pump– Check suction lines to make sure all connections are tight. Check the level of the chemical tank. Remove obstructions and clean strainers.

Pump is not accurate– Check the suction line and clean the strainer. Check for obstructions in suction lines, discharge lines, and injectors. Check the condition of the tube and roller. Ensure the roller is the correct match for the tube. (See Spare Parts)

The pump will not run and/or shows “Alarm”– Check to make sure the pump is in the proper operating Mode. Press the “Mode” key until the proper Mode is activated.

Check to see if the pump display shows “Alarm”——“报警”将表明TFD +(泄漏检测ion) has detected a solution/chemical in the pump head. Or the Flow Verification System “FVS” has been activated. If the tube has leaked, it must be replaced, and the pump head cleaned before re-starting. Press the Run/Standby key twice to clear “Alarm”. If the “FVS’ has triggered the Alarm, but no FVS Sensor is connected to the pump, de-activate the “FVS” by pressing “Field” and “Digit” keys at the same time, and then set delay to “000”.

“Service” is displayed on the screen– The “Service” display indicates that the pump has run for 500 hours since the last tube change, or since the last “Reset Service.” Depending on your pump usage and expected tube life, either replace the tube and reset “Service”, or reset “Service” to add 500 hours until next “Service” notice.

“Alarm” and “Service” are blinking– Programming error has occurred. Check that programming values are within limits.

Electricals

The A-100NVP will not power up– Check power source or try a different power source. Check to ensure the power cable is properly wired.

The input signal (4-20mA, 0-10V, Pulse) is dropping or incorrect– Check wiring integrity and proper connection to pump. Ensure signal is powered via 15-24VDC. Check that all signal cables are shielded and properly grounded. Ensure signal wiring is not located or run next to high voltage power or equipment generating EMI. Ensure power wiring to the pump is clean/conditioned.

" data-ai-bg-color="#dcdbe0" data-nonce="576de7c356" data-post-id="111053" data-url="//www.lrdcpa.com/help-center/flexflo-a-100nvp/a-100nvp-troubleshooting" data-bot-id="0" data-width="100%" data-height="600px" data-footer="true" data-has-bar="false" data-speech="" data-voice="" data-voice-error="" data-text_height="50" data-text_rounded="7" data-chat_rounded="7" data-voice_service="" data-voice_language="en-US" data-voice_name="en-US-Studio-M" data-voice_device="" data-voice_speed="1" data-voice_pitch="0" data-type="shortcode">
  • Ask me a question!

Processing......

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To选择或取消选择multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

Select Products

Pumps
Flow Meters
Skid Systems
Analyzers

Please review your selections before continuing.

Product Details
Select your industry:
How did you hear about us?