Blue-White - Chemical metering and fluid measurement solutions; chemical metering pumps, peristaltic pumps, diaphragm pumps, multi-diaphragm pumps, flow meters, flowmeters, variable area flow meters, paddlewheel flow meters, ultrasonic flow meters, engineered skid systems, single skid system, duplex skid system, triplex skid system, water analyzers...

Help Center

The Help Center is a self-service resource to view support articles, training videos, help topics, and best practices on our products. It also features our exclusive AI assistant, Oswald AI™, to assist you with any questions.

Oswald

Aquatics

FLEXFLO® A-100NA

Maintenance

General Maintenance

The A-100NA pump requires very little maintenance. However, the pump and all accessories should be checked weekly to ensure proper pump performance. This is especially important when pumping chemicals that may be extra corrosive. Inspect all components for signs of unusual wear, clogging, leaking, swelling, cracking, discoloration, or corrosion. Ensure rollers are moving freely and not straining or excessively wearing tubes. Replace worn or damaged components immediately.

Replacing Tubes and Rollers

The A-100NA pump is equipped with a Tube Failure Detection (TFD) that will sense a tube leak and stop the pump. This feature will prevent the pump from running when there is a tube leak.

When a tube leak occurs, or a tube needs to be replaced as part of periodic maintenance, the pump tube will need to be removed and a new tube will need to be installed. This process is quick and should not take more than a few minutes. Follow the steps below or watch the video at the bottom of this section.

  1. Turn the power switch to “OFF” to stop the pump.
  2. Relieve all pressure from the system.
  3. Disconnect the system plumbing from the pump tube adapters.
  4. Remove the three black thumb screws from the front of the pump head cover by unscrewing them counterclockwise.
  5. Remove the pump head cover by pulling it straight out.
  6. Turn the power switch to start the pump.
  7. With the pump running, pull the inlet (suction) fitting out of the pump head. Guide the tube counterclockwise away from the rollers. Pull the outlet (discharge) fitting out of the pump head.
  8. 停止泵。
  9. Thoroughly clean the pump head and rotor. The rotor can be removed by pulling it straight out. After cleaning, push the rotor back on the shaft.
  10. Start the pump.
  11. Insert the inlet (suction) side of the pump tube fitting into the lower retaining slot of the pump head. Carefully guide the pump tube into the pump head.
  12. Stretch the tube slightly and insert the outlet (discharge) fitting into the upper retaining slot of the pump head.
  13. Pull the outlet fitting out of the pump head.
  14. Place the clear cover onto the pump head. Secure the cover with the provided three thumb screws. The pump is now ready for operation.

A-100NA Tube Replacement Video:https://www.youtube.com/watch?v=NqhrR2Vs1OI&t=70s

Cleaning and Periodic Maintenance

The pump will require occasional cleaning and lubricating. The amount will depend on the severity of service.

When changing the pump tube assembly, the pump head chamber, roller assembly and pump head cover should be wiped free of any dirt and debris.

The pump head cover bearing may require grease periodically. Apply a small amount of grease (Aeroshell aviation grease #5 or equivalent) when necessary.

Although not necessary, 100% silicon lubrication may be used on the roller assembly.

Periodically clean the injection/check valve assembly, especially when injecting fluids that calcify such as sodium hypochlorite. These deposits and other build-ups can clog the fitting, increase the back pressure and interfere with the check valve operation.

Periodically clean the suction strainer.

Periodically inspect the air vents located under the motor compartment and on the rear panel. Clean if necessary.

" data-ai-bg-color="#dcdbe0" data-nonce="576de7c356" data-post-id="110946" data-url="//www.lrdcpa.com/help-center/flexflo-a-100na/a-100na-maintenance" data-bot-id="0" data-width="100%" data-height="600px" data-footer="true" data-has-bar="false" data-speech="" data-voice="" data-voice-error="" data-text_height="50" data-text_rounded="7" data-chat_rounded="7" data-voice_service="" data-voice_language="en-US" data-voice_name="en-US-Studio-M" data-voice_device="" data-voice_speed="1" data-voice_pitch="0" data-type="shortcode">
  • Ask me a question!

Processing......

Request a quote

Please fill out the form to request a quote.
A sales rep will reach out to you.

To选择或取消选择multiple products–desktop users hold [ctrl] on Windows or [cmd] on Mac and click products.

选择Products

Pumps
Flow Meters
Skid Systems
Analyzers

Please review your selections before continuing.

Product Details
选择your industry:
How did you hear about us?